TOMZN 4P 63A AUTO TRANSFER SWITCH (ATS)

Weight 1.90 kg
Dimensions 23 × 14 × 12 cm
SKU: TQG-4P-63

රු21,900.00 රු19,900.00

In Stock
  • Micro Switches
    Rated: voltage 380V 50/60HZ
    Max current: 63A.
    Noted: power will be interrupted when Switching.
    Switch time<;4S
    1. Dual power Automatic transfer switch can switch to Normal power or reserve power automatically. Please noted that the switch can’t turn on or turn off the generator. This switch Normal power first. If normal power on, the switch will switch to Normal power. If normal power off, and reserve power on, the switch will switch to reserve power.
    2.Wire
    Press the button to Automatic, the switch will switch to Normal power or reserve power automatically.
    Press the button to Manual, Then you have to switch the Direction manually.
    1.Application
    TOQ3D is terminal type automatic transfer device. It’s suitable for 3 phases 4 wires (or 1 phase 1 wire) dual power grid with AC 50/60Hz, rated voltage 400V/230V and rated current up to 63A. When one power goes wrong (only test normal Phase A voltage and reserve Phase A voltage, only test loss voltage or loss phase),it will automatic connect one or several load circuits from one power to the other power automatically, to ensure normal power supply of load circuits.
    The automatic transfer switch conforms to IEC60947-6-1 and GB/T14048.11
    2.Normal conditions for operation and installation:
    Environmental Temperature Condition:-5~+40°C
    Installation site is not more than 2000 meters above sea level.
    Pollution Level: Grade 3
    Installation Category: 3
    Vertical installation or horizontal installation
In Stock
Add to Wishlist
Add to Wishlist
Add to Wishlist
Add to Wishlist
SKU: TQG-4P-63 Categories: ,

Description

  • Micro Switches
    Rated: voltage 380V 50/60HZ
    Max current: 63A.
    Noted: power will be interrupted when Switching.
    Switch time<;4S
    1. Dual power Automatic transfer switch can switch to Normal power or reserve power automatically. Please noted that the switch can’t turn on or turn off the generator. This switch Normal power first. If normal power on, the switch will switch to Normal power. If normal power off, and reserve power on, the switch will switch to reserve power.
    2.Wire
    Press the button to Automatic, the switch will switch to Normal power or reserve power automatically.
    Press the button to Manual, Then you have to switch the Direction manually.
    1.Application
    TOQ3D is terminal type automatic transfer device. It’s suitable for 3 phases 4 wires (or 1 phase 1 wire) dual power grid with AC 50/60Hz, rated voltage 400V/230V and rated current up to 63A. When one power goes wrong (only test normal Phase A voltage and reserve Phase A voltage, only test loss voltage or loss phase),it will automatic connect one or several load circuits from one power to the other power automatically, to ensure normal power supply of load circuits.
    The automatic transfer switch conforms to IEC60947-6-1 and GB/T14048.11
    2.Normal conditions for operation and installation:
    Environmental Temperature Condition:-5~+40°C
    Installation site is not more than 2000 meters above sea level.
    Pollution Level: Grade 3
    Installation Category: 3
    Vertical installation or horizontal installation

Additional information

Weight 1.90 kg
Dimensions 23 × 14 × 12 cm

Reviews

There are no reviews yet.

Be the first to review “TOMZN 4P 63A AUTO TRANSFER SWITCH (ATS)”

Your email address will not be published. Required fields are marked *

Choose your Delivery Location
Enter your address and we will specify the offer for your area.
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Content
  • Weight
  • Dimensions
  • Additional information
Click outside to hide the comparison bar
Compare
Open chat
What can I do to assist you?